Elevator Phone
(Preview)
Where do other jurisdications require the elevator emergency phone to be received? The ASME A17.1 Elevator Code appears to be fairly ambiguous regarding the exact place to send the call. Any thoughts would be appreciated.
|
GaryL
|
0
|
973
|
|
|
|
|
Fire apparatus access via private driveways
(Preview)
Some interesting thoughts have arisen with our Development Review Staff regarding the need for a County Ordinance to address the lack of access to private single family dwellings via private driveways. Some of these driveways have bridges over creeks not capable of supporting fire apparatus, ov...
|
GaryL
|
0
|
1232
|
|
|
|
|
Attaching to sprinkler pipes
(Preview)
Hi, Can anyone tell me if there is a fire code that prohibits attaching anything to a fire sprinkler pipe. If there is, what is it or where can I find it.
|
Carlyle Engineer
|
5
|
18536
|
|
|
|
|
Portable extinguishers
(Preview)
We had a question recently and I wanted others to weigh in on this. The question is in regard to inspection, maintenance and recharging of portable extinguishers. NFPA 10 gives definitions and requirements for inspection, maintenance and recharging portable extinguishers. Does any locality al...
|
Anonymous
|
2
|
990
|
|
|
|
|
FAQ's on explosives
(Preview)
page (http://www.dhcd.virginia.gov/State_Fire_Marshal/Explos...
|
GDean
|
0
|
890
|
|
|
|
|
NFPA 25 Adoption to Virginia Admin. Code
(Preview)
Could anyone identify if the Admin. Code of Virginia adopted and incorporated NFPA 25 in its 1999 Supplement relating to the requirement for Fire Sprinkler Systems to be inspected monthly, to include flow testing and testing/checking of all valves?
If so, how were businesses and users notified...
|
EB
|
1
|
2818
|
|
|
|
|
Gas Grill
(Preview)
I live in a two bedroom apartment at an apartment complex, and I am planning on buying a gas grill which will be placed on my balcony.
- If the propane cylinder is less than 1 lb, is it legal?
- In case it is not legal, is a small tabletop grill legal?
Thanks,
-Ron
307.5...
|
Anonymous
|
0
|
1015
|
|
|
|
|
Apartment Laundry Room Fire Regulation
(Preview)
I live in an apartment building with several laundry rooms on each floor. Each room previously had a sign saying "This door must be kept closed due to fire regulations" or something to that affect. The painters took the signs down when they painted the doors and didn't replace the...
|
Anonymous
|
1
|
2358
|
|
|
|
|
Trapped Wet Piping in 13R System
(Preview)
NFPA 13 (1999) requires auxilliary drains for trapped sections of wet piping (5-14.2.5.2). There is no such requirement for a 13R system however there are some references to providing for system drainage. How do you folks treat a trapped section of wet pip...
|
MRedifer
|
4
|
1087
|
|
|
|
|
Emergency and Standby Power fire protection
(Preview)
Does anyone else interpret IFC section 604 to mean that all emergency and standby power generation systems have to be protected with 2-hour fire rated construction, including the fuel supply, fuel piping, controllers, generators, etc...? Or am I reading too much into the "not less than 2-h...
|
GaryL
|
3
|
1032
|
|
|
|
|
Gas grills - again
(Preview)
As a point of information, I'm repeating an email that was received through the SFMO email address. This is certainly not the first message of its type that's been received, it certainly is one of the better written comments on the subject even in light of its angry tone and, while I don't...
|
GDean
|
1
|
1094
|
|
|
|
|
Fire Underground Inspections
(Preview)
If anyone has established fire underground inspection and plan review checklists I would like to get a copy of them. Please send them via E-mail or snail mail, which ever is more convenient. E-mail me for my mailing address. Thanks in advance.
|
GaryL
|
0
|
891
|
|
|
|
|
Critical Intensity Factors
(Preview)
I am seeking critical intensity factors for numbers of inspectors. I'm thinking along the lines of #population = sq. footage of commercial space = # of inspectors type of equation, but I'll work with any others.
Does anyone have something they would like to share,...
|
Jan Mitchell
|
1
|
880
|
|
|
|
|
asbestos
(Preview)
I'm dealing with the issue of asbestos in structures that the county may have an interest in for holding live fire training evolutions. We have read & researched from the state to the federal levels, finding no real answers. We are dealing with both fribrous & non-fribrous tye...
|
Flo
|
0
|
860
|
|
|
|
|
Remote FDC's
(Preview)
I am looking for policies and/or ordinances regarding remote FDC's. Any samples or help would be great. Shawn
|
Shawn
|
0
|
960
|
|
|
|
|
Communication Lines
(Preview)
Has anyone had any dealings with fire alarm systems that are using cable tv phone lines? They are phone lines they run through your cable tv via a modem. We have a cable conmpany that is selling this service. One alarm company is refusing to use this means on communication. If anyone has dealt with this i...
|
Daniel
|
1
|
975
|
|
|
|
|
water flow switches
(Preview)
Can a vane type water flow switch be located between the bottom of the DPV and the connection off of the wet system? See NFPA 13 section 3-10.2.4 and NFPA 72 section 3-8.3.2.4.1. I say it is a simple NO! No vane type flow switches are permitted on a dry system. But I'm getting the ever popular "we do this all...
|
GaryL
|
1
|
1137
|
|
|
|
|
New Message Board
(Preview)
This is nice. Do you need to register as a new member or login to post topics or reply to messages? Thanks
|
Anonymous
|
3
|
1078
|
|
|